- Product Features
- Stent: GuReater
- Polymer :PLGA
- Design : Sine wave,8 crests 3-3-3 link,double-helix design
- Material : L605 CoCr based Alloy, laser cut
- Technical Parameters : Metal-artery ratio:15%
- Shortening:<1%
- Crossing profile:0.9-1.2mm
| Stent Length (mm) | Stent Diameter (mm) | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 2.25 | 2.5 | 2.75 | 3.0 | 3.5 | 4.0 | 4.5 | ||||
| 8 | LPRPC2208 | LPRPC2508 | LPRPC2708 | LPRPC3008 | LPRPC3508 | LPRPC4008 | / | |||
| 12 | LPRPC2212 | LPRPC2512 | LPRPC2712 | LPRPC3012 | LPRPC3512 | LPRPC4012 | LPRPC4512 | |||
| 15 | LPRPC2215 | LPRPC2515 | LPRPC2715 | LPRPC3015 | LPRPC3515 | LPRPC4015 | LPRPC4515 | |||
| 18 | LPRPC2218 | LPRPC2518 | LPRPC2718 | LPRPC3018 | LPRPC3518 | LPRPC4018 | LPRPC4518 | |||
| 21 | LPRPC2221 | LPRPC2521 | LPRPC2721 | LPRPC3021 | LPRPC3521 | LPRPC4021 | LPRPC4521 | |||
| 24 | LPRPC2224 | LPRPC2524 | LPRPC2724 | LPRPC3024 | LPRPC3524 | LPRPC4024 | LPRPC4524 | |||
| 29 | LPRPC2229 | LPRPC2529 | LPRPC2729 | LPRPC3029 | LPRPC3529 | LPRPC4029 | LPRPC4529 | |||
| 33 | LPRPC2233 | LPRPC2533 | LPRPC2733 | LPRPC3033 | LPRPC3533 | LPRPC4033 | LPRPC4533 | |||
| 3.5 | LPRPC2236 | LPRPC2536 | LPRPC2736 | LPRPC3036 | LPRPC3536 | LPRPC4036 | LPRPC4536 | |||
- Provide super flexibility and crossability
- Ensure the great compliance after implantation
- Drug completely released in 90 days
- PLGA coating completely degraded in 180 days
- Sharp and anti-friction blades, balance cuttingforce and flexibility
- Blades Working height is only 0.13mm, which could avoid blood vessel perforation
- Pre-made longitudinal neat blades, which could reduce the risk of intimal disordered tearing
- Sharp and anti-friction blades, balance cuttingforce and flexibility
- lmprove crossability
- Optimize retraction
- lmprove crossability
- Optimize retraction
GuReater CoCr Sirolimus-eluting Coronary Stent system are indicated for improving coronary luminal diameter in Patients with symptomatic ischemic heart disease, coronary occlusion , acute coronary artery syndrome, vascular dissection and/or laceration.
| Expansion Pressure kPa(atm) | Stent Diameter (mm) | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 2.5 | 2.75 | 3.0 | 3.5 | 4.0 | 4.5 | |||||
| 2.75 | 2.35 | 2.60 | 2.84 | 3.37 | 3.86 | 4.35 | ||||
| 3 | 2.40 | 2.66 | 2.89 | 3.42 | 3.92 | 4.41 | ||||
| 3.5 | 2.45 | 2.71 | 2.95 | 3.47 | 3.97 | 4.47 | ||||
| 2.75 | 2.47 | 2.73 | 2.97 | 3.50 | 4.00 | 4.5 | ||||
| 2.75 | 2.50 | 2.75 | 3.00 | 3.54 | 4.04 | 4.55 | ||||
| 2.75 | 2.56 | 2.82 | 3.06 | 3.61 | 4.11 | 4.60 | ||||
| 2.75 | 2.62 | 2.88 | 3.12 | 3.68 | 4.18 | 4.69 | ||||
| 2.75 | 2.68 | 2.94 | 3.18 | 3.75 | 4.26 | 4.78 | ||||
| 2.75 | 2.75 | 3.00 | 3.25 | 3.81 | 4.33 | 4.85 | ||||
| 2.75 | 2.81 | 3.06 | 3.30 | 3.88 | 4.40 | 4.92 | ||||
| 2.75 | 2.86 | 3.12 | 3.36 | 3.95 | 4.47 | 4.99 | ||||