GuReater® CoCr Sirolimus-eluting Coronary Stent System

Products
GuReater® CoCr Sirolimus-eluting Coronary Stent System

GuReater® CoCr Sirolimus-eluting Coronary Stent System

GuReater® CoCr Sirolimus-eluting Coronary Stent System
GuReater® CoCr Sirolimus-eluting Coronary Stent System
Enquire Now
Product features
  1. Product Features

    - Stent: GuReater

    - Polymer :PLGA

    - Design : Sine wave,8 crests 3-3-3 link,double-helix design

    - Material : L605 CoCr based Alloy, laser cut

    - Technical Parameters : Metal-artery ratio:15%

    - Shortening:<1%

    - Crossing profile:0.9-1.2mm

Ordering Information
Stent Length (mm) Stent Diameter (mm)
2.25 2.5 2.75 3.0 3.54.04.5
8 LPRPC2208 LPRPC2508 LPRPC2708 LPRPC3008 LPRPC3508LPRPC4008/
12 LPRPC2212 LPRPC2512 LPRPC2712 LPRPC3012 LPRPC3512LPRPC4012LPRPC4512
15 LPRPC2215 LPRPC2515 LPRPC2715 LPRPC3015 LPRPC3515LPRPC4015LPRPC4515
18 LPRPC2218 LPRPC2518 LPRPC2718 LPRPC3018 LPRPC3518LPRPC4018LPRPC4518
21 LPRPC2221 LPRPC2521 LPRPC2721 LPRPC3021 LPRPC3521LPRPC4021LPRPC4521
24 LPRPC2224 LPRPC2524 LPRPC2724 LPRPC3024 LPRPC3524LPRPC4024LPRPC4524
29 LPRPC2229 LPRPC2529 LPRPC2729 LPRPC3029 LPRPC3529LPRPC4029LPRPC4529
33 LPRPC2233 LPRPC2533 LPRPC2733 LPRPC3033 LPRPC3533LPRPC4033LPRPC4533
3.5 LPRPC2236 LPRPC2536 LPRPC2736 LPRPC3036 LPRPC3536LPRPC4036LPRPC4536
Clinical Studies
  • Fig.2 Clinical Outcomes 9 Months After Stent Implantation(GuReater:N=251; Partner:N=262; p>0.05)
  • Fig.3 Clinical Outcomes 9 Months After Stent Implantation (GuReater: N=251; Partner: N=262; p>0.05)
  • Fig.4 Clinical results one year after stent implantation (GuReater: N=251; Partner: N=262; p>0.05)
Product features
75umCoCrStrut
  • Provide super flexibility and crossability
  • Ensure the great compliance after implantation
Microscopic view of stable drug coating for GuReaterTM during degradation
PLGABiodegradablePolymer of Drug Coating
  • Drug completely released in 90 days
  • PLGA coating completely degraded in 180 days
Segmented Microsurgical blades Design
  • Sharp and anti-friction blades, balance cuttingforce and flexibility
  • Blades Working height is only 0.13mm, which could avoid blood vessel perforation
  • Pre-made longitudinal neat blades, which could reduce the risk of intimal disordered tearing
Segmented Microsurgical blades Design
  • Sharp and anti-friction blades, balance cuttingforce and flexibility
Semi-compliant balloon
  • lmprove crossability
  • Optimize retraction
Semi-compliant balloon
  • lmprove crossability
  • Optimize retraction
Indications

GuReater CoCr Sirolimus-eluting Coronary Stent system are indicated for improving coronary luminal diameter in Patients with symptomatic ischemic heart disease, coronary occlusion , acute coronary artery syndrome, vascular dissection and/or laceration.

Ordering Information
Expansion Pressure kPa(atm) Stent Diameter (mm)
2.5 2.75 3.0 3.5 4.0 4.5
2.75 2.35 2.60 2.84 3.37 3.86 4.35
3 2.40 2.66 2.89 3.42 3.92 4.41
3.5 2.45 2.71 2.95 3.47 3.97 4.47
2.75 2.47 2.73 2.97 3.50 4.00 4.5
2.75 2.50 2.75 3.00 3.54 4.04 4.55
2.75 2.56 2.82 3.06 3.61 4.11 4.60
2.75 2.62 2.88 3.12 3.68 4.18 4.69
2.75 2.68 2.94 3.18 3.75 4.26 4.78
2.75 2.75 3.00 3.25 3.81 4.33 4.85
2.75 2.81 3.06 3.30 3.88 4.40 4.92
2.75 2.86 3.12 3.36 3.95 4.47 4.99

Product registration and availability vary by country. For more information on product availability, please contact us

Thank You for Your Attention on Lepu Medical!

Email us with any questions or inquiries or use our contact data. We would be happy to answer your questions.

Submit
Submit