Vesscide Cutting Balloon System

Products
Vesscide Cutting Balloon System

Vesscide Cutting Balloon System

Vesscide Cutting Balloon System
Vesscide Cutting Balloon System
Enquire Now
Product Details
  • Performance Tips
  • Structure Indication and Technical Parameters
  • Can be expanded repeatedly, do not reverse the catheter between two expansions
  • Structure indication and technical parameters2

    1.Hub | 2. Hypotube | 3. Side hole | 4. Inner tube | 5. Balloon | 6. Blade | 7. Tip

    1.Adapted guiding catheter: Minimum guiding catheter 1.8mm/6
    3.The effective length of the catheter:1400mm
    2.Adapted guiding catheter: Minimum guiding catheter 1.8mm/6
    4.Marker location: Both ends of the balloon
Ordering Information
Indications

The Cutting Balloon Dilatation Catheter is indicated to be applled for patients with atherosclerotic plaques in the coronary arteries that need to be cut.

  • Calcifed lesions
  • Ostia lession and bifurcation lesions
  • Stent restenosis Small vessel lessions
Product features
Segmented Microsurgical blades Design
  • Sharp and anti-friction blades, balance cuttingforce and flexibility
  • Blades Working height is only 0.13mm, which could avoid blood vessel perforation
  • Pre-made longitudinal neat blades, which could reduce the risk of intimal disordered tearing
Segmented Microsurgical blades Design
  • Sharp and anti-friction blades, balance cuttingforce and flexibility
Semi-compliant balloon
  • lmprove crossability
  • Optimize retraction
Semi-compliant balloon
  • lmprove crossability
  • Optimize retraction
Segmented Microsurgical blades Design
  • Sharp and anti-friction blades, balance cuttingforce and flexibility
  • Blades Working height is only 0.13mm, which could avoid blood vessel perforation
  • Pre-made longitudinal neat blades, which could reduce the risk of intimal disordered tearing
Segmented Microsurgical blades Design
  • Sharp and anti-friction blades, balance cuttingforce and flexibility
Semi-compliant balloon
  • lmprove crossability
  • Optimize retraction
Semi-compliant balloon
  • lmprove crossability
  • Optimize retraction
How it works
Why choose Vesscide?
  1. Dilated under low pressure

    Can benefit from vascular lumen

  2. Change the compliance of the lession

    Reduce the axial migration of plaque, and decrease lumen elastic retraction.

  3. Cutting the lession neatly and orderly

    Reduce the risk of irregular dissection and acute occlusion

  4. Anchoring the lession precisely

    Avoid balloon slipping, and squeeze plaque by larger area

Balloon Compliance

This product is presented for academic exchange purpose only and is not intended for sale within European Union.