Vesselin Drug Coated Coronary Balloon Catheter

Products
Vesselin Drug Coated Coronary Balloon Catheter

Vesselin Drug Coated Coronary Balloon Catheter

Vesselin Drug Coated Coronary Balloon Catheter
Vesselin Drug Coated Coronary Balloon Catheter
Enquire Now
Product Details
  • Structure indication and technical parameters
  • 1. The effective length of the cathetor: 135cm
    2. The compatible guidewire: 0.014'' inch
Antiproliferative drugs
  1. Paclitaxel: highly lipophilicity, long half-life, rapid absorption. long-lasting efficacy
  2. Drug concentration:3 ug/mm
  3. Drug loading matrix:

    - Urea: natural non-toxic, high hydrophilicity, rapid metabolism in the human body, promotion of rapid drug release

  4. Development mark:

    - Platinum Marker, one at each end of the balloon

  5. Delivery system:

    - New generation of rapid-exchange balloon catheter

Ordering Information
Diameter /mm Length (mm)
9 12 16 20 2428313538
2.0 LPCDB 20009 LPCDB 20012 LPCDB 20016 LPCDB 20020 LPCDB 20024LPCDB 20028LPCDB 20031LPCDB 20035LPCDB 20038
2.5 LPCDB 25009 LPCDB 25012 LPCDB 25016 LPCDB 25020 LPCDB 25024LPCDB 25028LPCDB 25031LPCDB 25035LPCDB 25038
2.75 LPCDB 27009 LPCDB 27012 LPCDB 27016 LPCDB 27020 LPCDB 27024LPCDB 27028LPCDB 27031LPCDB 27035LPCDB 27038
3.0 / LPCDB 30012 LPCDB 30016 LPCDB 30020 LPCDB 30024LPCDB 30028LPCDB 30031LPCDB 30035LPCDB 30038
3.5 LPCDB 35009 LPCDB 35012 LPCDB 35016 LPCDB 35020 LPCDB 35024LPCDB 35028LPCDB 35031LPCDB 35035LPCDB 35038
4.0 / LPCDB 400012 LPCDB 400016 LPCDB 400020 LPCDB 400024LPCDB 400028LPCDB 400031LPCDB 400035LPCDB 400038
4.5 LPCDB 45009 LPCDB 45012 LPCDB 45016 LPCDB 45020 LPCDB 45024LPCDB 45028LPCDB 45031LPCDB 45035LPCDB 45038
Indications
  • Stent Restenosis
  • Small Vascular Disease
  • Bifurcation Lesion
How it works
Product features
Drug Coating
  • Coating with Active Pharmaceutical Ingredients grade urea, provide better biocompatibility, facilitate drug releasing effectively. Drug release rate in vivo achieves more than 90%.
  • Suitable particle size at 2-3um enables long term efficacy and low embolism risk
Drug
  • Paclitaxel loaded with drug dose at 3ug/mm2, inhibits restenosis continuously
Materials
  • Improved PEBAX material, lower crossing profile guarantees higher flexibility and enhanced crossability
Delivery System
  • Spiral cut hypotube design,strengthens the transition section, brings optimized deliver-ability for transition.
Segmented Microsurgical blades Design
  • Sharp and anti-friction blades, balance cuttingforce and flexibility
  • Blades Working height is only 0.13mm, which could avoid blood vessel perforation
  • Pre-made longitudinal neat blades, which could reduce the risk of intimal disordered tearing
Segmented Microsurgical blades Design
  • Sharp and anti-friction blades, balance cuttingforce and flexibility
Semi-compliant balloon
  • lmprove crossability
  • Optimize retraction
Semi-compliant balloon
  • lmprove crossability
  • Optimize retraction
Efficient Drug Release, Stable and Firm Coating

1. Before balloon dilatation, about 98% of paclitaxel can reach the lesion site.

2.During balloon dilatation, about 90% of paclitaxel is effectively released.

Balloon Compliance

Thank You for Your Attention on Lepu Medical!

Email us with any questions or inquiries or use our contact data. We would be happy to answer your questions.

Submit
Submit